Air foil Fan Sirocco Fan
Model Discharge flange diameter (mm) Charge flange out diameter (mm) Output (KW)
K1D08 240x300 φ325 0.75×2.2
K1D10 300x380 φ400 2.2、3.7
K1D12 360x460 φ475 0.75、1.5、5.5
K1D14 420x540 φ540 1.5×3.7
K1D16 480x610 φ625 3.7×7.5
K1D18 540x690 φ700 5.5×11
K1D20 600x770 φ810 11×18.5
K1D22 660x850 φ890 15、18.5
Model Discharge flange diameter (mm) Charge flange out diameter (mm) Output (KW)
M2D06 180x230 φ240 0.75、1.5
M2D08 240x300 φ325 0.75×5.5
M2D10 300x380 φ400 1.5×15
M2D12 360x460 φ475 3.7×11
M2D14 420x540 φ540 7.5×18.5
   
Turbo fans Turbo Blower
Model Discharge flange diameter (mm) Charge flange out diameter (mm) Output (KW)
T1D08 270x190 φ265 1.5、2.2
T1D10 340x205 φ335 3.7×7.5
T1D12 400x245 φ400 7.5×18.5
T1D14 470x285 φ475 15×30
T2D08 270x190 φ265 0.75、1.5
T2D10 340x205 φ335 1.5×3.7
T2D12 400x245 φ400 3.7×11
T2D14 470x285 φ475 7.5×15、22
T2D16 540x325 φ540 15×22
Model Discharge flange diameter (mm) Charge flange out diameter (mm) Output (KW)
B1D14 88x70 JIS 5K 150A _166.6 2.2、3.7
B1D15 110x80 JIS 5K 200A _218 3.7、5.5
B1D16 131x100 JIS 5K 200A _218 5.5、7.5
B1D17 156x125 JIS 5K 200A _218 7.5、11
B1D18 200x160 JIS 5K 250A _269.5 11、18.5
B1D19 250x200 JIS 5K 300A _321 18.5、30
B1D20 300x250 JIS 5K 300A _321 30、45

product photo  
Maintenance Simplification

Maintenance-free. No adjustment required, with only a few consumable goods and accessories.

 

1. Since the impeller and electric motor axle are directly coupled, there is no need to adjust belt tension or exchange belts.
2. The electric motors in this series use a sealed bearing so there is no need to re-grease.
3. The bearing is longer lasting compared to belt driven machines.
4. Drive unit can be pulled out from the back with the impeller on, so the rotor can be taken down and repaired easily without taking off the intake and discharge pipes.

 

NOTICE
If there is a foundation bolt implanted into the ground, you cannot pull out the drive unit by sliding it towards the back. (If you would like to have the drive unit to be pulled out by sliding towards the back, we can make special orders.) You may have to take off the electric wirings of the electric motor due to the electric wirings∏ position.

Saving space
The electric blower occupies less space.
Compared to belt driven machines, the space is reduced by up to 50%.
High safety

Considering safety, there are no exposed rotating parts.

 

 